Occu-Med

Lead Testing Requirements

Federal OSHA Medical Surveillance · Quick Reference

Inorganic lead causes neurological, renal, hematologic, reproductive, and cardiovascular harm; affects general-industry and construction workers in smelting, battery manufacturing, painting/abatement, welding, and demolition. Federal OSHA requires employers to provide this medical surveillance at no cost to covered employees. Routine testing catches harm early and keeps your program audit-ready.

Required Tests by Exam

Required test / evaluationBaselinebefore first assignment at or above the action levelPeriodicwhile exposed at or above the action level
Blood lead level (BLL)✓every 6 mo*
Zinc protoporphyrin (ZPP)✓every 6 mo*
Detailed work & medical historypast lead exposure; smoking and hygiene; GI, blood, kidney, heart, reproductive, and nervous-system history✓annual†
Physical examinationteeth, gums, blood, GI, kidney, heart, and nervous systems; lungs if a respirator will be used✓annual†
Blood pressure✓annual†
Hemoglobin, hematocrit, red-cell indices, blood smear✓annual†
BUN and serum creatininekidney function✓annual†
Urinalysis with microscopic exam✓annual†
Any other test the physician deems necessary✓annual†

Blood lead & ZPP testing schedule 29 CFR 1910.1025(j)(2), via 1915.1025

SituationTest at leastStandard
Each covered employeeEvery 6 months(j)(2)(i)(A)
Last blood lead at or above 40 µg/100 gEvery 2 months, until two consecutive results are below 40 µg/100 g(j)(2)(i)(B)
During the removal period of an employee removed for an elevated blood leadMonthly(j)(2)(i)(C)
Blood lead at or above the medical-removal levelFollow-up blood test within 2 weeks(j)(2)(ii)

We run this program for you.

Scheduling, exams, lab panels, physician review, and audit-ready records — fully Federal OSHA compliant.

(559) 435-2800 x102
ccoyle@occu-med.com